GLMGS121
Asialeren
8517710000
Availability: | |
---|---|
Quantity: | |
PDF Export | |
Parameter | Conditions | Min | Type | Max | Units | |
Freq. Range | Ant – Any Port, Unused Ports -50Ω(1) | 1.1 | 1.7 | GHz | ||
Gain(2) -Amplified(Norm) -Amplified(Hi Iso) | Ant-Any Port, Unused Ports-50(1) (Gain may be specified by the customer) | 20 | 21 | 24 | dB | |
9 | 10 | 11 | ||||
0dB | Ant- any Port, ,Unused Ports - 50Ω(1) | -1 | 0 | 1 | dB | |
Input/output VSWR | All Ports 50Ω(1) | 1.5:1 | 2.0:1 | - | ||
Noise Figure- Amplified | Ant-Any Port, Unused Ports-50Ω(1) Gain=20dB | 2.0 | dB | |||
Amp. Balance | ІJ1-J2І,Ant-Any Port, Unused Ports-50Ω(1) | 0.5 | dB | |||
Phase. Balance | Phase(J1-J2),Ant-Any Port,Unused Port -50Ω(1) | 1.0 | deg | |||
Delay -Passive -Amplified | Ant-Any Port, Unused Ports-50Ω(1), L1 | 3 | ns | |||
5 | ||||||
Isolation -Amp/Pass(Norm) -Amplified (Hi Iso.) | Adjacent Ports: Ant - 50Ω(1) | 13 | dB | |||
Alternate Ports: Ant – 50Ω(1) | 21 | |||||
Adjacent Ports: Ant - 50Ω(1) | 35 | |||||
Alternate Ports: Ant - 50Ω(1) | 44 | |||||
DC IN | DC Input on any RF Output | 4 | 12 | VDC | ||
DC Ripple | 300 Hz to 1MHz | 50 | mV pk-pk | |||
Device Current | Current Consumption of Active device, excluded Ant. Cur. | 18 | 20 | mA | ||
Ant/Thru Current(3) | Max source DC current through device | 250 | mA | |||
Antenna Monitor(4) | Ioc | Range for Open Circuit Threshold | 15 | 75 | mA | |
Isc | Range for Short Circuit Threshold(5) | 100 | 180 | mA | ||
Surge Protection | 8/20us | 4 | KA |
The GLMGS121 is a GPS device with one end input and two end outputs, which usually divides the received signal from the active GPS receiving antenna into two outputs for GPS receiving equipment.
Both outputs of the MGS12i are powered on at the same time. The power divider internally selects the port for powering the active GPS antenna by comparing the voltages.
When the voltage values of the two output ports are different, the higher voltage port will be used to supply power to the active GPS antenna. The other port will have a 200 Ohm DC load to simulate any receiver antenna connected to this port DC loss.
When the two output ports have the same voltage value, the J1 port is used by default for power supply.
The J2 port will have a 200 Ohm DC load
l Gain 0dB, 21dB And Passive Version Available
l Output port power at the same time intelligent selection of high voltage power supply.
l Response For
Ø Galileo:L1,E1,E2,E5(E5a,E5b),E6;
Ø Beidou2:B1,B2,B3;
Ø IRNSS:L1,L5;
Ø OmniStar
l High Isolations > 28dB
VSWR(1575.42MHz) | Gain 0dB(1575.42MHz) | |
IN | 1.16 | |
OUT1 | 1.10 | 0.04dB |
OUT2 | 1.08 | -0.22dB |
Output port power supply (V) | ||||||||
OUT1 | 5.00 | 6.00 | 5.00 | 6.00 | 4.00 | 5.00 | 5.00 | 0.00 |
OUT2 | 5.00 | 6.00 | 6.00 | 5.00 | 5.00 | 4.00 | 0.00 | 5.00 |
IN | 4.81 | 5.78 | 5.85 | 5.75 | 4.91 | 4.75 | 4.71 | 4.70 |
Parameter | Conditions | Min | Type | Max | Units | |
Freq. Range | Ant – Any Port, Unused Ports -50Ω(1) | 1.1 | 1.7 | GHz | ||
Gain(2) -Amplified(Norm) -Amplified(Hi Iso) | Ant-Any Port, Unused Ports-50(1) (Gain may be specified by the customer) | 20 | 21 | 24 | dB | |
9 | 10 | 11 | ||||
0dB | Ant- any Port, ,Unused Ports - 50Ω(1) | -1 | 0 | 1 | dB | |
Input/output VSWR | All Ports 50Ω(1) | 1.5:1 | 2.0:1 | - | ||
Noise Figure- Amplified | Ant-Any Port, Unused Ports-50Ω(1) Gain=20dB | 2.0 | dB | |||
Amp. Balance | ІJ1-J2І,Ant-Any Port, Unused Ports-50Ω(1) | 0.5 | dB | |||
Phase. Balance | Phase(J1-J2),Ant-Any Port,Unused Port -50Ω(1) | 1.0 | deg | |||
Delay -Passive -Amplified | Ant-Any Port, Unused Ports-50Ω(1), L1 | 3 | ns | |||
5 | ||||||
Isolation -Amp/Pass(Norm) -Amplified (Hi Iso.) | Adjacent Ports: Ant - 50Ω(1) | 13 | dB | |||
Alternate Ports: Ant – 50Ω(1) | 21 | |||||
Adjacent Ports: Ant - 50Ω(1) | 35 | |||||
Alternate Ports: Ant - 50Ω(1) | 44 | |||||
DC IN | DC Input on any RF Output | 4 | 12 | VDC | ||
DC Ripple | 300 Hz to 1MHz | 50 | mV pk-pk | |||
Device Current | Current Consumption of Active device, excluded Ant. Cur. | 18 | 20 | mA | ||
Ant/Thru Current(3) | Max source DC current through device | 250 | mA | |||
Antenna Monitor(4) | Ioc | Range for Open Circuit Threshold | 15 | 75 | mA | |
Isc | Range for Short Circuit Threshold(5) | 100 | 180 | mA | ||
Surge Protection | 8/20us | 4 | KA |
The GLMGS121 is a GPS device with one end input and two end outputs, which usually divides the received signal from the active GPS receiving antenna into two outputs for GPS receiving equipment.
Both outputs of the MGS12i are powered on at the same time. The power divider internally selects the port for powering the active GPS antenna by comparing the voltages.
When the voltage values of the two output ports are different, the higher voltage port will be used to supply power to the active GPS antenna. The other port will have a 200 Ohm DC load to simulate any receiver antenna connected to this port DC loss.
When the two output ports have the same voltage value, the J1 port is used by default for power supply.
The J2 port will have a 200 Ohm DC load
l Gain 0dB, 21dB And Passive Version Available
l Output port power at the same time intelligent selection of high voltage power supply.
l Response For
Ø Galileo:L1,E1,E2,E5(E5a,E5b),E6;
Ø Beidou2:B1,B2,B3;
Ø IRNSS:L1,L5;
Ø OmniStar
l High Isolations > 28dB
VSWR(1575.42MHz) | Gain 0dB(1575.42MHz) | |
IN | 1.16 | |
OUT1 | 1.10 | 0.04dB |
OUT2 | 1.08 | -0.22dB |
Output port power supply (V) | ||||||||
OUT1 | 5.00 | 6.00 | 5.00 | 6.00 | 4.00 | 5.00 | 5.00 | 0.00 |
OUT2 | 5.00 | 6.00 | 6.00 | 5.00 | 5.00 | 4.00 | 0.00 | 5.00 |
IN | 4.81 | 5.78 | 5.85 | 5.75 | 4.91 | 4.75 | 4.71 | 4.70 |